§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR HINGES IN THE ENTRANCE LOCATED AT APT C1, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT D2, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 3; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT D4, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD PANEL FROM FLOOR TO CEILING CREATING LIVING SPACE IN THE 2nd ROOM FROM NORTH LOCATED AT APT D4, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 6; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT D7, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 6; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT C1, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 5; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR HINGES IN THE ENTRANCE LOCATED AT APT B2, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SUBFLOORING WOOD IN THE BATHROOM LOCATED AT APT D2, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 6; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT C8, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT D1, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 5; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT D6, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR HINGES IN THE ENTRANCE LOCATED AT APT D7, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
ENTIRE BUILDING
ENTIRE BUILDING
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER AND LOWER WINDOW SASH BALANCE STUCK AT NORTH WALL BETWEEN 2ND AND 3RD STORY , 2nd STORY
ENTIRE BUILDING
ENTIRE BUILDING
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT B4, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT B4, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING KNOB AT RADIATOR SUPPLY VALVE IN THE 1st ROOM FROM NORTH LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL AND BUZZER AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS IN THE PRIVATE HALLWAY LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DECORATION WOOD COVERING WALL AT ALL WALLS IN THE 2nd ROOM FROM NORTH LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
Self Service
SLOW LEAK
ENTIRE BUILDING
ENTIRE BUILDING
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE UPPER WINDOW SASH AT INTERMEDIATE LANDING 1ST WINDOW FROM SOUTH AT PUBLIC HALL, 2nd STORY
WATER SUPPLY
ENTIRE BUILDING
DOOR
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT D3, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MAIL BOX FOR APT.D1 AT VESTIBULE , 1st STORY
SLOW LEAK