§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§ 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY-DUTY LOCK AND LATCH SET AT BUILDING ENTRANCE DOOR , 1st STORY
§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT BUILDING ENTRANCE DOOR , 1st STORY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 4B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Apt: 4B
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATHTUB IN THE BATHROOM LOCATED AT APT 4B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Apt: 4B
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Apt: 4C
§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE GARBAGE BAGS AT FIRE PASSAGE WAY
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 4B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Apt: 4B
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT BATHTUB IN THE BATHROOM LOCATED AT APT 4B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Apt: 4B
§ 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT THE BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY