2322 28 AVENUE, Queens, NY, 11102 · New York City · 25 total events
Construct new seven (7) story school building as per plans filed.
Plumbing work as per plans filed.
INSTALLATION OF AN ADT ACCESS SYSTEM AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION. SCAFFOLD TO COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2022.
ONE (1) SYPDER MINI-CRANE WILL BE USED FOR ERECTION OF CURTAIN WALL, SCREEN WALL, ANDGLASS BOX FEATURE FOR 7-STORY BUILDING.
Install and use GBL workhorse material lifting crab.
Install temporary dry standpipe system during construction as per plans filed. No change to use, egress, or occupancy. Filed in conjunction with NB#X00658182-I1
TEMPORARY PIPE SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
TEMPORARY WORK PLATFORM AS PER DRAWINGS. WORK PLATFORM SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Installation of gas boiler as per plans filed herewith.
TEMPORARY HOIST RUN-BACK STRUCTURE DURING NEW BLDG CONSTRUCTION, FILED SEPARATELY. HOIST RUN-BACK STRUCTURE SHALL COMPLY WITH CH #33 OF THE NYC BLDG CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. HOIST & ELEVATOR APPL SUBMITTED SEP
EQUIPMENT USE: DUAL 7000 # CAPACITY PERSONNEL/MATERIAL HOISTS DURING NB CONST, FILED SEP. HOISTS SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. ELEVATOR APPLICATION SUBMITTED SEPARATELY
CONSTRUCTION FENCE AS PER DRAWINGS DURING NB CONST, FILED SEP. CONSTRUCTION FENCE SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. DOT PERMITS BY OTHERS FOR FENCE INSTALLED ON SIDEWALK/ROADWAY.
HEAVY DUTY SIDEWALK SHED DURING NB CONST, FILED SEP. SIDEWALK SHED SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. DOT PERMITS BY OTHERS FOR SHED INSTALLED ON SIDEWALK/ROADWAY
Installation of emergency generator fuel storage as per plans filed herewith. Filed in conjunction with MS: X00658182-S5.
INSTALLATION OF STEEL PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
Installation of emergency generator fuel storage as per plans filed herewith. Filed in conjunction with MS: X00658182-S5.
Install combined sprinkler/standpipe system as per plans filed in conjunction with NB #X00658182-I1
Install combined sprinkler/standpipe system as per plans filed in conjunction with NB #X00658182-I1
Mechanical work as per plans filed. Filed in conjunction with NB#X00658182-I1. Mechanical work also includes ventilation and exhaust for commercial kitchen hoods and equipment.
APARTMENT ONLY
Provide support of excavation and underpinning (SOE) as per plans filed. Filed in conjunction with NB#X00658182-I1
Installation of 8' high temporary plywood construction fence
Installation of temporary supported scaffold per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
Installation of temporary heavy duty sidewalk shed per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
Installation of temporary heavy duty sidewalk shed per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.