1851 PUTNAM AVENUE— Violations & Issues

Loading chart data...

Top Violations

Paint/Plaster23
Water Leak15
Door/Lock13
Pest Infestation5
Roof/Ceiling5

Top 311 Complaints

PLUMBING7
UNSANITARY CONDITION6
DOOR/WINDOW5
HEAT/HOT WATER5
ELECTRIC5
Class B - HazardousNOV SENT OUT

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR KNOB AT DOOR AT ENTRANCE IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2R

Sep 24, 2025
Class B - HazardousNOV SENT OUT

§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2R

Sep 24, 2025
Class B - HazardousNOV SENT OUT

§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2R

Sep 24, 2025
Class B - HazardousNOV SENT OUT

§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2R

Sep 24, 2025
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2R

Sep 24, 2025
Class B - HazardousNOV SENT OUT

§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2R

Sep 24, 2025
Class B - HazardousNOV SENT OUT

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR AT ENTRANCE IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2R

Sep 24, 2025
Class C - Immediately HazardousNOV SENT OUT

§ 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH AND CLEANABLE, POSITIVE LEAD-BASED PAINT IN AN APARTMENT WITH A CHILD UNDER SIX LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2R

Sep 24, 2025
Class C - Immediately HazardousNOV SENT OUT

§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM EAST AT SOUTH WALL, 1st DOOR FRAME FROM EAST AT SOUTH WALL IN THE FOYER LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2R

Sep 24, 2025
Class B - HazardousNOV SENT OUT

§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2R

Sep 24, 2025