Back to building

133-28 BLOSSOM AVENUE— Violations & Issues

Loading chart data...

Top Violations

Paint/Plaster8
Pest Infestation5
Water Leak4
Smoke/CO Detector3
Roof/Ceiling3

Top 311 Complaints

UNSANITARY CONDITION6
WATER LEAK3
ELECTRIC2
DOOR/WINDOW2
Dirty Condition1
Class B - HazardousNOV SENT OUT

§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT WEST WALL IN THE BATHROOM LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1STFLO

Oct 26, 2022
Class B - HazardousNOV SENT OUT

§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE IN THE KITCHEN LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1STFLO

Oct 26, 2022
Class B - HazardousNOV SENT OUT

§ 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1STFLO

Oct 26, 2022
Class A - Non-HazardousNOV SENT OUT

§ 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS, CEILING & TRIM IN THE ENTIRE APARTMENT LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1STFLO

Oct 26, 2022
Class B - HazardousNOV SENT OUT

§ 27-2038 ADMIN CODE: PROVIDE ADEQUATE LIGHTING FOR MINIMUM 60 WATTS INCANDESCENT OR EQUIVALENT AT PUBLIC HALL, 1st STORY

Aug 17, 2022
Class B - HazardousNOV SENT OUT

§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOODEN BASE CABINET AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1, 1st STORY

Apt: 1

Aug 17, 2022
Class B - HazardousNOV SENT OUT

§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY

Apt: 1

Aug 17, 2022
Class B - HazardousNOV SENT OUT

§ 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1

Jul 22, 2022
Class B - HazardousNOV SENT OUT

HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1FL

Jul 22, 2022
Class B - HazardousNOV SENT OUT

§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1

Jul 22, 2022