Back to building

242 EAST 79 STREET— Violations & Issues

Loading chart data...

Top Violations

Door/Lock8
Heat/Hot Water2
Pest Infestation2
Electrical2
Fire Escape/Stairs1

Top 311 Complaints

General Construction/Plumbing4
HEAT/HOT WATER2
Noise - Commercial2
Noise2
Noise - Residential2
Class C - Immediately HazardousNOV SENT OUT

§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM . AT BOILER ROOM

Dec 13, 2025
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3B, 4th STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 3B

Dec 13, 2025
Class C - Immediately HazardousNOTICE OF ISSUANCE SENT TO TENANT

HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 4th STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 3B

Dec 2, 2025
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE PROVIDE OPERABLE HANDLE AT BULKHEAD DOOR EXTERIOR TO ALLOW INGRESS FROM ROOF TO BULKHEAD LANDING LOCATED AT PUBLIC PARTS

Nov 28, 2025
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF PUSH PADDLE ALARM DEVICE AT BULKHEAD DOOR LOCATED AT PUBLIC PARTS

Nov 28, 2025
Class B - HazardousNOV SENT OUT

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT BULKHEAD DOOR LOCATED AT PUBLIC PARTS

Nov 28, 2025
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR IN THE ENTRANCE LOCATED AT APT 3B, 4th STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 3B

Nov 28, 2025
Class C - Immediately HazardousNOV SENT OUT

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT BULKHEAD LOCATED AT PUBLIC PARTS

Nov 28, 2025
Class C - Immediately HazardousNOV SENT OUT

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AND DOOR IN THE ENTRANCE LOCATED AT APT 1B, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH

Apt: 1B

Nov 28, 2025
Class C - Immediately HazardousNOV SENT OUT

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AND DOOR AT TRASH ROOM LOCATED AT PUBLIC PARTS, 2nd STORY

Nov 28, 2025
1–10 of 18
page 1 / 2