Top Violations

Door/Lock32
Paint/Plaster9
Roof/Ceiling8
Smoke/CO Detector6
Fire Escape/Stairs6

Top 311 Complaints

HEAT/HOT WATER8
WATER LEAK4
PAINT/PLASTER3
PLUMBING3
ELECTRIC1
Class B - HazardousVIOLATION CLOSED

§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST

Apt: 3E

Mar 13, 2025
Class B - HazardousVIOLATION CLOSED

§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST

Apt: 3E

Mar 13, 2025
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY

Mar 6, 2025
Class B - HazardousFIRST NO ACCESS TO RE- INSPECT VIOLATION

§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ..... IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH

Apt: 3E

Feb 26, 2025
Class B - HazardousVIOLATION CLOSED

§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH

Apt: 3E

Feb 26, 2025
Class B - HazardousFIRST NO ACCESS TO RE- INSPECT VIOLATION

§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH

Apt: 3E

Feb 26, 2025
Class B - HazardousVIOLATION CLOSED

§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH

Apt: 3E

Feb 26, 2025
Class B - HazardousFIRST NO ACCESS TO RE- INSPECT VIOLATION

§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH

Apt: 3E

Feb 26, 2025
Class B - HazardousVIOLATION CLOSED

§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT FIRE ESCAPE AT SOUTHEAST COURT YARD

Sep 25, 2023
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT ID, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST

Apt: ID

May 12, 2023