681 OCEAN AVENUE— Violations & Issues

Loading chart data...

Top Violations

Paint/Plaster374
Pest Infestation96
Window/Guard88
Flooring80
Water Leak79

Top 311 Complaints

UNSANITARY CONDITION66
Elevator51
PLUMBING50
PAINT/PLASTER38
WATER LEAK28
Class B - HazardousNOV SENT OUT

§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT F6, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH

Apt: F6

Jun 17, 2026
Class C - Immediately HazardousCIV14 MAILED

HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT F6, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH

Apt: F6

Jun 17, 2026
Class A - Non-HazardousNOV SENT OUT

§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A STOP AT TOP OF GUIDE RODS SO AS TO PREVENT REMOVAL OF DROPLADDER AT 1ST FROM NORTH AT BUILDING FRONT AT FIRE ESCAPE

Jun 17, 2026
Class B - HazardousNOV SENT OUT

§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT F6, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH

Apt: F6

Jun 17, 2026
Class A - Non-HazardousNOV SENT OUT

§ 27-2042 ADM CODE PROVIDE A MIRROR IN SELF-SERVICE ELEVATOR ARRANGED SO AS TO ENABLE A PERSON ENTERING, TO VIEW INSIDE OF ELEVATOR NUMBER 3P801 AT BUILDING NORTH SECTION

Jun 17, 2026
Class C - Immediately HazardousCIV14 MAILED

HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT E6, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH

Apt: E6

Jun 17, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL APPROX. 5 SQ. FT. IN THE BATHROOM LOCATED AT APT E6, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST

Apt: E6

May 28, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WINDOW COUNTER BALANCE IN THE KITCHEN LOCATED AT APT E6, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST

Apt: E6

May 28, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT E6, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST

Apt: E6

May 28, 2026
Class C - Immediately HazardousNOTICE OF ISSUANCE SENT TO TENANT

HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT E6, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST

Apt: E6

May 28, 2026