(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
§ 27-2005 HMC: IMMEDIATELY PROVIDE A FIRE GUARD AS DIRECTED BY THE NYC DEPT. OF HOUSING PRESERVATION & DEVELOPMENT (HPD) AND/OR THE NYC DEPT. OF BUILDINGS (DOB) TO PROTECT AGAINST FIRE HAZARDS OBSERVED BY HPD AND/OR DOB. FIRE HAZARDS OBSERVED BY HPD HAVE RESULTED IN THE FOLLOWING ADDITIONAL HPD VIOLATION(S): . INOPERABLE SPRINKLER SYSTEM IN THE PUBLIC HALL. OS&Y VALVE TURNED OFF AT CELLAR CAUSE UNKNOWN. IN ORDER TO PROTECT PUBLIC SAFETY AGAINST IMMINENT FIRE HAZARDS OBSERVED, A FIRE GUARD MUST BE PROVIDED FORTHWITH FOR CONTINUOUS 24 HOUR COVERAGE, NOTWITHSTANDING THE CORRECTION AND CERTIFICATION DATES SET FORTH ABOVE (THE CORRECTION AND CERTIFICATION DATES SET FORTH ABOVE ARE APPLICABLE FOR PURPOSES OF CIVIL PENALTIES THAT MAY BE ASSESSED PURSUANT TO NYC ADMINISTRATIVE CODE § 27-2115, BUT DO NOT REFLECT THE DATE BY WHICH A FIRE GUARD MUST BE PROVIDED). A FIRE GUARD MUST BE PROVIDED IMMEDIATELY DUE TO THE EXIGENCY OF THE DANGEROUS FIRE HAZARD CONDITIONS OBSERVED. THE VIOLATION REQUIRING A FIRE GUARD TO BE PROVIDED WILL REMAIN OPEN UNTIL SUCH TIME AS THE FIRE HAZARDS RESULTING IN THE HPD VIOLATION(S) REFERENCED ABOVE AND/OR THE FIRE HAZARDS RESULTING IN RELATED DOB VIOLATION(S) HAVE BEEN DISMISSED.
§ 27-2050 ADM CODE PROVIDE A PIECE OF GARDEN HOSE 10 FEET IN LENGTH WITH FEMALE COUPLING AND A 10 QUART PAIL ON PREMISES TO TEST SPRINKLER SYSTEM.
§ 27-2005, 2050 HMC: PROVIDE AN ADEQUATE SUPPLY OF WATER FOR THE WET SPRINKLER AND/OR STANDPIPE SYSTEM AT PUBLIC HALL
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 3FL, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Apt: 3FL
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS 10 THAN SQ.FT AT 1st CLOSET FROM EAST AT SOUTH WALL CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 3FL, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Apt: 3FL
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3FL, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Apt: 3FL
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Apt: 3FL
§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE WATER LINE AT SINK IN THE KITCHEN LOCATED AT APT 3FL, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Apt: 3FL
§ 27-2005 HMC: REFIT DOOR TO TERRACE AT SOUTH IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 3FL, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Apt: 3FL