Back to building

2000 QUENTIN ROAD— Violations & Issues

Loading chart data...

Top Violations

Paint/Plaster33
Door/Lock13
Smoke/CO Detector8
Mold/Mildew6
Window/Guard3

Top 311 Complaints

HEAT/HOT WATER20
Noise - Residential10
SAFETY7
Abandoned Vehicle7
Lead4
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT COMPACTOR CLOSET, 1st STORY

Dec 17, 2024
Class B - HazardousVIOLATION DISMISSED

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT COMPACTOR CLOSET DOOR AT 1ST STORY AT COMPACTOR CLOSET, 1st STORY

Dec 17, 2024
Class A - Non-HazardousVIOLATION DISMISSED

§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2D

Oct 22, 2024
Class A - Non-HazardousVIOLATION DISMISSED

§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2D

Oct 22, 2024
Class C - Immediately HazardousVIOLATION DISMISSED

§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2D

Oct 22, 2024
Class A - Non-HazardousVIOLATION DISMISSED

§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st CLOSET FROM NORTH AT EAST WALL DOOR FRAME, 1st DOOR FRAME FROM EAST AT SOUTH WALL IN THE FOYER LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2D

Oct 22, 2024
Class B - HazardousVIOLATION DISMISSED

§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT THE SOUTH WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17363980 ISSUED 22-OCT-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).

Apt: 2D

Oct 22, 2024
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM NORTH AT EAST WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2D

Oct 22, 2024
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM EAST AT SOUTH WALL IN THE FOYER LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2D

Oct 22, 2024
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) WEST WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 2D

Oct 22, 2024
1–10 of 70
page 1 / 7