Top Violations

Heat/Hot Water2
Paint/Plaster2
Mold/Mildew1
Door/Lock1
Smoke/CO Detector1

Top 311 Complaints

UNSANITARY CONDITION5
Request Large Bulky Item Collection4
Noise - Residential3
Illegal Parking3
Graffiti3
Class C - Immediately HazardousNOV SENT OUT

§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 3B

Apr 26, 2026
Class B - HazardousFIRST NO ACCESS TO RE- INSPECT VIOLATION

§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WALL APPROX 5SQ FT IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 15754738 ISSUED 03-MAR-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).

Apt: 3B

Mar 3, 2023
Class A - Non-HazardousVIOLATION DISMISSED

§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND SOUTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 3B

Mar 3, 2023
Class A - Non-HazardousVIOLATION DISMISSED

§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 3B

Sep 14, 2022
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE EAST DOOR IN THE 3rd ROOM FROM EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1B

Sep 4, 2019
Class B - HazardousVIOLATION DISMISSED

§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE 3rd ROOM FROM EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1B

Sep 4, 2019
Class C - Immediately HazardousVIOLATION DISMISSED

§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 5; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1B

Sep 4, 2019
Class B - HazardousVIOLATION DISMISSED

§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT SHEETROCK CEILING AT BOILER ROOM IN THE 3rd ROOM FROM EAST LOCATED AT APT 1B LOWER LEVEL, 1st STORY, 1st APARTMENT FROM NORTH AT EAST

Apt: 1B

Sep 4, 2019