Back to building

911 SIMPSON STREET— Violations & Issues

Loading chart data...

Top Violations

Paint/Plaster26
Pest Infestation17
Door/Lock16
Smoke/CO Detector12
Window/Guard10

Top 311 Complaints

HEAT/HOT WATER29
UNSANITARY CONDITION25
DOOR/WINDOW19
ELECTRIC17
PAINT/PLASTER12
Class C - Immediately HazardousNOV SENT OUT

567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT ALL YARDS THROUGHOUT

Apr 13, 2026
Class C - Immediately HazardousNOV SENT OUT

§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING 7TH, 11TH, 12TH , 13TH TREAD FROM BOTTOM AT 1ST STACK FROM EAST AT NORTH EXTERIOR WALL AT FIRE ESCAPE, 1st STORY

Apr 13, 2026
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING 9TH 10TH AND 11TH TREAD UP FROM BOTTOM AT 2ND FIRE ESCAPE FROM SOUTH AT EAST EXTERIOR WALL AT FIRE ESCAPE, 2nd STORY

Oct 20, 2025
Class A - Non-HazardousNOV SENT OUT

§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER TACK WELEDED, PRPERLY SECUREBY USING APPROPRIATE NUTS AND BOLTS TO SECURE AT 1ST FIRE ESCAPE FROM NORTH AT EAST BUILDING FRONT AT FIRE ESCAPE

Oct 5, 2025
Class A - Non-HazardousNOV SENT OUT

§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER TACK WELEDED, PRPERLY SECUREBY USING APPROPRIATE NUTS AND BOLTS TO SECURE AT 2ND FIRE ESCAPE FROM NORTH AT EAST BUILDING FRONT AT FIRE ESCAPE

Oct 5, 2025
Class A - Non-HazardousVIOLATION DISMISSED

(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.

Jun 5, 2025
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY

Apr 30, 2025
Class B - HazardousNOV SENT OUT

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE 2ND TREAD FROM BOTTOM AT PUBLIC HALL STAIRS, 1st STORY

Apr 30, 2025
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEDING 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 33, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH

Apt: 33

Dec 14, 2024
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE ENTIRE APARTMENT LOCATED AT APT 33, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH

Apt: 33

Dec 14, 2024
110 of 130