Top Violations

Paint/Plaster73
Window/Guard26
Door/Lock18
Smoke/CO Detector12
Flooring10

Top 311 Complaints

HEAT/HOT WATER85
Noise - Residential49
Noise - Street/Sidewalk15
PAINT/PLASTER13
UNSANITARY CONDITION11
Class A - Non-HazardousNOV SENT OUT

§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMATION/REQUIRED-SIGNAGE.PAGE

May 28, 2026
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOOR , 1st STORY

Jan 30, 2026
Class B - HazardousNOV CERTIFIED ON TIME

§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIAL (SHEET ROCK, GROUT ) AT PUBLIC HALL, 1st STORY

Jan 14, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIALS (SHEETROCK) AT PUBLIC HALL, 1st STORY

Dec 21, 2025
Class C - Immediately HazardousNOTICE OF ISSUANCE SENT TO TENANT

HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST

Apt: 2D

Dec 7, 2025
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT 2ND FIRE ESCAPE FROM NORTH AT WEST EXTERIOR WALL BUILDING FRONT AT FIRE ESCAPE

Oct 11, 2025
Class A - Non-HazardousNOV SENT OUT

§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL BALCONIES AT 2ND FIRE ESCAPE FROM NORTH AT WEST EXTERIOR WALL (BUILDING FRONT) AT FIRE ESCAPE

Oct 11, 2025
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT 2ND LOWER SASH WINDOW FROM NORTH AT EAST WALL AT 1ST STORY AT PUBLIC HALL

Oct 11, 2025
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SEALED WINDOW AT 1ST WINDOW FROM NORTH AT EAST WALL AT 1ST STORY AT PUBLIC HALL

Oct 11, 2025
Class C - Immediately HazardousNOV SENT OUT

§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCREWS AT 1ST WINDOW FROM NORTH AT EAST WALL AT 1ST STORY AT PUBLIC HALL

Oct 11, 2025