HOIST CABLE REPLACEMENT ON ONE(1) 2500LB CAPACITY, 20-FLOOR, 700FPM, PASSENGER ELEVATOR(H), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV000024)
HOIST CABLE REPLACEMENT ON ONE(1) 2500LB CAPACITY, 20-FLOOR, 700FPM, PASSENGER ELEVATOR(H), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV000024)
THE STERLING HALL FOOD CLUB - NON-ILLUMINATED WINDOW SIGN - (S CLARK ST ELEVATION) - 4'-6"H X 8'-4"W (38 SQFT)
THE STERLING HALL FOOD CLUB - INTERNALLY ILLUMINATED WALL SIGN - (W ADAMS ST ELEVATION) - 4'-6"H X 22'-0"W (99 SQFT)
THE STERLING HALL FOOD CLUB - INTERNALLY ILLUMINATED WALL SIGN - (S CLARK ST ELEVATION) - 4'-6"H X 22'-0"W (99 SQFT)
LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL DATA/VIDEO. SPECIFIC LOCATION: SUITE 900.
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 156 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: 9TH FLOOR.
REVISION TO ORIGINAL SELF CERT PERMIT #101053676 PER REQUEST FROM TASK FORCE INSPECTOR COMMENTS DATED 10/8/2024. REVISED ADDRESS FROM 61 W ADAMS TO 125 S CLARK AND REVISED DRAWINGS TO REFLECT MINIMAL SCOPE UPDATES PER VALUE ENGINEERING EXERCISE (OMITTED NEW FIXTURES AND REUSED EXISTING, NO CHANGE TO EGRESS PATHS). SELF-CERT 2019 CBRC. INTERIOR BUILD-OUT OF SUITE 900 AT 125 S CLARK STREET, AN EXISTING COMMERCIAL OFFICE SPACE IN A 20 STORY COMMERCIAL BUILDING. NO CHANGE IN OCCUPANCY (OCCUPANCY GRO
SELF-CERT: SUITE 1000 - PARTIAL DEMOLITION OF EXISTING TENANT BUILD-OUT AND FINISHES. ARCHITECTURAL SCOPE OF WORK TO INCLUDE NEW INTERIOR FINISHES AND RELOCATED LIGHTING. OVERALL SCOPE ALSO INCLUDES RELATED ELECTRICAL, MECHANICAL, AND FIRE PROTECTION WORK.
DOUBLE SIDED ILLUMINATED SIGN IN WINDOW; 19 SQ/FT; 9 SQ/FT OF TEXT; WEST ELEVATION
TEMPORARY SCAFFOLDING: QTY: 2, MAX. LENGTH: 200 FT., MAX. HEIGHT: 240 FT. LOCATION: WEST ELEVATION. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE THIS PERMIT IS NOT VALID WITHOUT CORRESPONDING CDOT PUBLIC WAY PERMIT.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 2600 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: SOUTH AND WEST FACADE.
FIREPROOF EXISTING OPENINGS AND REPAIR CRACKS, LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), 5TH FLOOR.
HARDWIRE OPEN AREA WORKSTATIONS ON THE 5TH FLOOR. CIRCUITS BY OTHERS
HARDWIRE OPEN AREA WORKSTATIONS ON THE 5TH FLOOR. CIRCUITS BY OTHERS
**FIRE ALARM PERMIT****FIRE ALARM SYSTEM**INSTALLATION OF ACCESS CONTROL SYSTEM PER NFPA SECT. 101 ON 5TH FLOOR. INSTALLATION OF MAG LOCK PER OCCUPANCIES LISTED 13-160-261 & 269.
**FIRE ALARM PERMIT****FIRE ALARM SYSTEM**INSTALLATION OF ACCESS CONTROL SYSTEM PER NFPA SECT. 101 ON 5TH FLOOR. INSTALLATION OF MAG LOCK PER OCCUPANCIES LISTED 13-160-261 & 269.
DATA CABLING
DATA CABLING
SPR 2019 CBRC: INTERIOR ALTERATIONS TO OFFICE SUITE 500 FOR A NEW 303 S.F. IT SERVER ROOM. WORK TO INCLUDE NEW PARTITIONS, ELECTRICAL AND MECHANICAL INCLUDING A SUPPLEMENTAL COOLING UNIT, FOR A NEW IT SERVER ROOM. AS PER PLANS. 1A CONSTRUCTION. B-BUSINESS