FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2019)
No description available
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
INSP *2018 -FTM-345-355 KINGSLAND AVE HAD AN OCCUPIED 3-STORY VERTICAL ADDITION COMBIND W/O PERMITS.STRUCT STEEL NOT COMPLIANT.COLUMNS DO NOT [email protected] PLATES MISSING.LOOSE BOLTS.STEEL LATERL FRAME NOT STIFF.NYSPE ENGINEER EVALUATE ENTRE BLDG IMMED.PROV REPRS UNDER PERMIT PER EVALUATION BY PE.COMPLETE REPRS UNDER PERMIT&SIGNOFF BY 12/21/20
INSP *2018 -FTM-345-355 KINGSLAND AVE COMBIND COMRCL BLDG HAD VERTICAL ENLRGMENT IN PROG,W/OUT PRMT.CMU WALLS INSTL W/OUT PRMT.DO NOT PREVENT MOVEMENT IN BOTH DIRECTIONS.MULTIPL LOCATION CRACKS IN CMU.PE ENGINEER IMMED EVALUATE ENTIRE BLDG.PROVIDE REPRS ACHIEVE CODE COMPLIANCE UNDER PRMT PER EVALUATION.COMPLETE REPRS UNDER PRMT AND SIGNOFF BY 12/21/20
INSP *2018 -FTM-345-355 KINGSLAND AVE COMRCL BLDG HAD VERT ENLRGEMT IN PROG,W/OUT PRMT AND CMU WALLS IN STATE DISREP.MULTI CRACKS IN PLASTER FRME@EXP1 KINGLAND AVE.OPEN JOINTS&CRACKS IN EXP'D MASN@EXP1,2,&3 ALNG MONITOR ST WALLS.NYSPE IMMED EVAL ENTIRE BLDG&MASN WALLS.PROVIDE REPRS UNDR PRMT PER EVAL BY PE.COMPLT REPRS UNDR PRMT & SIGNOFF BY 12/21/20
No description available
INSP *2018 -FTM-COMRCL BLDG AT SO.END OF THRU-LOT,HAD VERT ENLARGEMENT WITHOUT PRMT IN PROGRESS WITH 1 STRY ADDEPHT REAR.CMU WALL TIES DO NOT PREVENT MOVEMENT IN BOTH DIRECTIONS.STEEL AND METAL DECK INSTL WITHOUT PRMT.PE TO IMMED EVALUATE ENTRE BLDG.PROVID REPRS UNDR PRMT TO ACHIEVE CODE COMPLIANCE PER EVALUATION PE.COMPLT REPRS AND SIGNOFF BY 12/21/20
INSP *2018 -FTM-341 KINGSLAND AVE HAD VERT ENLARGEMNT W/OUT PERMIT IN PROGRES.POST&WALLS DETERIOR DUE TO CELLAR FLOODING.WD FLOORING BUCKLED AT FIRST FLR.EXTER STAIR ROOF&STAIR CORRODED.EXTER WALLS IN DISREPAIR NYSPE TO IMMED EVALUATE ENTIRE BLDG.PROVIDE REPAIRS UNDER PERMIT PER EVALUATION BY PE.COMPLETE REPAIRS UNDER PERMIT AND SIGNOFF BY 12/21/20
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2018
No description available
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4