230 WEST 107 STREET, Manhattan, NY, 10025 · New York City · 503 total events
APARTMENT ONLY
ENTIRE BUILDING
APARTMENT ONLY
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCHSET AT COMPACTOR CLOSET DOOR 1ST STORY PUBLIC HALL AT PUBLIC HALL, 1st STORY
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCHSET AT COMPACTER CLOSET DOOR 2ND STORY PUBLIC HALL AT PUBLIC HALL, 2nd STORY
APARTMENT ONLY
NO LIGHTING
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE EXCHUCHEON PLATE AT CEILING AT RISER IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH
STEAM PIPE/RISER
CEILING
APARTMENT ONLY
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Judgment: NO
NO LIGHTING
ENTIRE BUILDING
NO LIGHTING
NO LIGHTING
PESTS
NO LIGHTING
Installation of a temporarily heavy-duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
NO LIGHTING
CEILING
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
PESTS
PESTS
TOILET
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE DOOR TO THE APARTMENT PANEL AT WEST WALL IN THE FOYER LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
BELL/BUZZER/INTERCOM
MOLD
BELL/BUZZER/INTERCOM
§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
TOILET
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. LIVE LOAD 300PSF.
FACADE REPAIRS AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
File-SUSPENDED SCAFFOLD OUTRIGGER SYSTEMS FOR FAADE RESTORATION AND INSPECTION. ALSO, INSTALL MATERIAL HOIST ON ROOF.
APARTMENT ONLY
APARTMENT ONLY
APARTMENT ONLY
APARTMENT ONLY
TOILET
TOILET
WALL
BATHTUB/SHOWER
WALL
WALL
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AROUND BATHTUB WALLS IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
§ 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE MECHANICAL STOPPER AT BATHTUB IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST