HEREBY FILING FOR THE DIRECT REPLACMENT OF ROOT TOP UNIT. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
WATER SUPPLY
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
HEREBY FILING FOR THE DIRECT REPLACEMENT OF ROOF TOP UNIT. NO CHANGE TO USE OCCUPANCY OR EGRESS.
FILING FOR SPRINKLER SYSTEM TO REMOVE 30 EXISTING PENDANTS AND INSTALL 30 UPRIGHT HEADS IN THE CELLAR. REPAIR AND REPLACE EXISTING PIPING AS REQUIRE AND INSTALL 10 NEW UPRIGHT HEADS ON THE FIRST FLOOR.
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
EXTERIOR MASONRY REPAIRS FOR THE CHIMNEY AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
REPLACE (2) 10,000 GALLON FUEL STORAGE TANKS WITH (1) 7,500 GALLON FUEL STORAGE TANK AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
STRUCTURAL SUPPORT FOR NEW COOLING TOWER INSTALLATION AS PER PLANS FILED.
Replacement of cooling tower at roof level as per plans filed herewith.
Throne--Installation of mechanical equipment with related duct and piping as per plans filed herewith.
INSTALL NEW CHIMNEY LINER AS PER PLANS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
FIT OUT OF A LIQUOR STORE IN AN EXISTING RETAIL WHITE BOX SPACE. INSTALLATION OF RAISED FLOOR, PAINTING OF OPEN CEILING, INSTALLATION OF STORE FIXTURES, FURNITURES, AND ARCHITECTURAL ITEMS. NO WORK TO THE EXISTING STOREFRONT OR EXTERIOR WALL
NEW INSTALLATION OF ONE (1) WATER-SOURCE HEAT PUMP UNIT IN RETAIL SPACE. NO UNITS OR COMPONENTS TO BE INSTALLED ON THE EXTERIOR. NEW ASSOCIATED DISTRIBUTION DUCTWORK. NEW CONDENSER WATER PIPING TO CONNECT TO EXISTING.
REINFORCEMENT OF EXISTING ROOF BEAM. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
Throne-- Installation of plumbing fixtures in conjunction with commercial gym build-out.
General construction inclusive of partitions modifications for commercial gym as per plans filed.
Modification, relocation and installation of new duct work in cellar and 1st floor.
INTERIOR DEMOLITION INCLUSIVE OF INTERIOR PARTITIONS, CEILINGS, AND MECHANICAL DUCT/EQUIPMENT ON 1ST AND CELLAR.
modifications to an existing HVAC system
MOSDIFICATIONS TO AN EXISTING SPRINKLER SYSTEM
INSTALLATION OF PLUMBING FIXTURES
MH WORK. NO CHNAGE OF USE, EGRESS OR OCCUPANCY
THIS IS AN INTERIOR REMODEL OF AN OFFICE SPACE IN THE FIRST FLOOR. THE PROPOSED CONSTRUCTION WORK SHALL HAVE NO-BEARING PARTITION, ELECTRICAL SYSTEMWORK, MILLWORK, FINISHES. NO STRUCTURAL ALTERATIONS AREPROPOSED.
sprinkler job filed. no change of use, egress or occupancy.
PLUMBING WORK. NO CHNAGE OF USE, EGRESS OR OCCUPANCY
SP-001.01 - Superseded - Updated drawing listSP-003.01 - Superseded - Revised sprinkler countSP-101.01 - Superseded - Revised sprinkler count SP-201.01 - Superseded - Revised sprinkler layout per as-built condition and updated sprinkler count
P-001.01 - Superseded - Updated drawing listP-101.01 - Superseded - Revised layout in pantry, addition of mop sink and floor drain in janitors closet.P-201.01 - Superseded - Revised sanitary and domestic water riser diagrams per plan changes.
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
MODIFICATIONS TO AN EXISTING HVAC SYSTEM