4 2 STREET, Brooklyn, NY, 11231 · New York City · 6 total events
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
No description available
EMG WRK ORDER: BLDG HAD APPROX 100'OF BRICK PARAPET PART COLLAP ONTO 3 VEHICLES&INTO THE STREET ALONG WALNUT AVE APPROX 75'OF PARAPET@WALNUT AVE WAS UNSTAB&AT RISK OF COLLAP PARAPET WALLS@2ST BLDG WERE BULGING ALONG 139&140 ST OWN TO ENG PE&ENDOR CONT TO IMMED REMOVE UNSTABLE PAR APET WALL&INST S/W/S FILE W/IN 2 DAYS ST OF WRK DEMO N/L/THAN 3/22/19
FTM:APPROX 100 LINEAR FEET OF PARAPET WALL COLLAP ONTO 3 VEHICLES&IN STREET ALONG WALNUT AVE ON 3/20/19 PARAPET HAD INADEQUATE BRICK TIES& HEADER COURSES BTWN THE 2 WYTHES PARAPET ALONG E 139&140@2ST BLDG WERE BULGING OWN ENGAGE NYSPE TO EVAL THE ENTIRE ALL PARAPETS&FACADES PE TO PREPARE RPR PLANS&WRK TO BEGIN UNDER PRMT BY 7/1/19&COMPL BY 7/1/2020
INSTALL APPROX. 200 LINEAR FT OF SWS ALONG EXP#1(WALNUT AVE)APPROX 58 LINEAR FT AROUND CORNER OF EXP#2(EAST 139 ST) & APPROX. 58 LINEAR FT AROUND CORNER OF EXP#4 (EAST 140 ST) IN TOTAL APPROX. 316 LINEAR FT OF SWS TO BE ERECTED TO SAFEGUARD PUBLIC & PROPERTY