2102 BEVERLEY ROAD, Brooklyn, NY, 11226

Brooklyn, NY 11226Built 19587 floors75 units
106 violationsOwner: 2102 REALTY LLC

Tenant Reviews (0)

No reviews yet. Be the first to review this building!

Advertisement
Loading chart data...

Violations by Unit

(9 units)
UnitViolationsOpen
Apt 6H
C:8B:5A:24
370
Common Areas
C:11B:8A:4
230
Apt 5L
C:4B:7A:5
160
Apt 2L
C:1B:7A:2
100
Apt 3B
C:2B:5A:2
90
Apt 6E
B:4A:2
60
Apt 7F
C:2
20
Apt 2K
C:1B:1
20
Apt 4F
B:1
10
Advertisement
Class C - Immediately HazardousNOTICE OF ISSUANCE SENT TO TENANT

HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 7F, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 7F

Jan 28, 2026
Class C - Immediately HazardousCIV14 MAILED

§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 7F, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH

Apt: 7F

Jan 28, 2026
Class C - Immediately HazardousNOV CERTIFIED ON TIME

§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM

Jan 28, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RUBBER GASKET AT UPPER AND LOWER DOOR AT REFRIGERATOR IN THE KITCHEN LOCATED AT APT 5L, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT EAST

Apt: 5L

Jan 17, 2026
Class C - Immediately HazardousCIV14 MAILED

HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5L, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT EAST

Apt: 5L

Jan 17, 2026
Class A - Non-HazardousNOV CERTIFIED ON TIME

§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY CAPS FOR ELECTRICAL OUTLETS AT EAST AND WEST WALL AT PUBLIC HALL, 4th STORY

Jan 17, 2026
Class B - HazardousNOV SENT OUT

§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH

Apt: 6E

Jan 10, 2026
Class A - Non-HazardousNOV SENT OUT

§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 2nd BATHROOM FROM EAST AT SOUTH, THE 3rd BATHROOM FROM EAST AT NORTH, THE PRIVATE HALLWAY , THE 3rd ROOM FROM EAST AT NORTH, THE KITCHEN , THE FOYER , THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH

Apt: 6E

Jan 10, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH WALL IN THE 3rd BATHROOM FROM EAST AT NORTH LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH

Apt: 6E

Jan 10, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH COUNTER BALANCE AT 1ST WINDOW FROM WEST AT NORTH IN THE KITCHEN LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH

Apt: 6E

Jan 10, 2026
Class B - HazardousNOV SENT OUT

§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH

Apt: 6E

Jan 10, 2026
Class A - Non-HazardousNOV SENT OUT

§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH

Apt: 6E

Jan 10, 2026
Class C - Immediately HazardousNOV SENT OUT

567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT RATS AT ALL YARDS

Jan 8, 2026
Class C - Immediately HazardousNOV CERTIFIED ON TIME

§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF REFRIGERATOR DISCARDED WITH DOORS INTACT AT WEST YARD

Jan 8, 2026
Class B - HazardousNOV CERTIFIED ON TIME

§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING PADLOCK AND CHAIN AT IRON GATE TO FENCE , WEST YARD

Jan 8, 2026
Class B - HazardousNOV SENT OUT

§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRACKS, AT EXTERIOR BRICK WALL WITH DETERIORAD AND MISSING MORTAR AT JOINTS , NORTHWEST SECTION, 6TH STORY , BUILDING FRONT YARD

Jan 8, 2026
Class C - Immediately HazardousNOV CERTIFIED ON TIME

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT VESTIBULE DOOR AT BASEMENT AT PUBLIC HALL

Dec 24, 2025
Class C - Immediately HazardousVIOLATION CLOSED

§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BULKHEAD DOOR AT ROOF , 6th STORY

Nov 14, 2025
Class B - HazardousCIV14 MAILED

§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 7th APARTMENT FROM SOUTH AT WEST

Apt: 4F

Nov 11, 2025
Class A - Non-HazardousVIOLATION DISMISSED

§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT SOUTH WALL, SOUTH WINDOW FRAME AND AT CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH

Apt: 3B

Nov 1, 2025

Building Details

Owner
2102 REALTY LLC
View Portfolio →
Building Class
D1
Land Use
3
Residential Units
75
BBL
3051520001