ERECT ONE (1) SCAFFOLD DATES 09/14/2022 THROUGH 09/14/2023
POST APPROVED OCCUPANCY CARD
PERMIT EXPIRES ON 10/19/2022 ERECTION STARTS: 9/16/2022, ERECTION ENDS: 9/18/2022. TENT- 1 DAY EVENT (9/17/2022) U OF C RUBENSTEIN FOR UMERECT ONE (1) 30X60 (9MX18M) STRUCTURE TENT. ERECT 9/16/2022- REMOVE 9/18/2022 ASSEMBLY
PERMIT EXPIRES ON 05/28/2022 ERECTION STARTS: 4/4/2022, ERECTION ENDS: 10/4/2022. TENT- SELF-CERT- REINSTATE PERMIT 100944496- 180 DAY EVENT (4/6/2022-10/2/2022) UOFC RUBENSTEIN FORUME RECT ONE (1) 30X40 (9MX12M) STRUCTURE TENT. ERECT 04/04/2022- REMOVE 10/04/2022ASEMBLY
PERMIT EXPIRES ON 01/04/2022 ERECTION STARTS: 10/28/2021, ERECTION ENDS: 11/9/2021. ERECTION STARTS: 10/28/2021, ERECTION ENDS: 11/9/2021. TENT- SELF-CERT 12 DAY EVENT (10/28/2021-11/8/2021) UOFC RUBENSTEIN FORUMERECT ONE (1) 30X40 (9MX12M) STRUCTURE TENT. ERECT 10/28/2021- REMOVE 11/09/2021ASSEMBLY
SECURITY WORK (UNIVERSITY OF CHICAGO) CXSO210629O
SECURITY SYS. WORK (UNIV. OF CHICAGO) CXSO210507G
**FIRE ALARM PERMIT**MODIFICATION OF AN EXISTING, CHICAGO APPROVED HIGH RISE (PER 13-76) VOICE EVACUATION/FIRE ALARM SYSTEM, TO ACCOMMODATE TENANT BUILD OUT. BUILDING HAS MIXED OCCUPANCY & IS FULLY SPRINKLERED.
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
NEW CONSTRUCTION FOR COMPLETION OF ELECTRICAL WORK IN ROOMS 202 (IN WALL ROUGH) AND ROOMS 601 & 901 (FURNITURE CONNECTIONS). (REFERENCE ORIGINAL BUILDING PERMIT NUMBER 100761744)
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
INSTALL OF LOW VOLTAGE AUDIO VISUAL CABLING IN CONDUIT PROVIDED BY OTHERS. INSTALL OF AV EQUIPMENT (PROJECTORS, MONITORS)
HVAC WIRING
PD #43-INTERIOR ALTERATIONS TO AN EXISTING MERCANTILE SPACE TO CONSTRUCT A NEW WINE BAR PER PLANS.
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
INSTALLATION OF (4) GEARLESS, 4500# CAP., PASSENGER ELEVATORS;#FE1 & PE2 SERVING 11-STOPS, 350 PFM; #PE21 SERVIVG 11-STOPS, 350 FPM; #PE3 SERVING 4-STOPS, 200 FPM; (1) HYDRAULIC, 4500# CAP., 3-STOP, 150 FPM, PASSENGER ELEVATOR #FE2. PURSUANT TO PLANS SUBMITTED.
INSTALLATION OF ONE (1) RAXTAR RX3245 SINGLE CAR TEMPORARY CONSTRUCTION HOIST, 7000LB.CAP, 200FPM, 11-FOOR PERSONNEL HOIST PASSENGER ELEVATOR. PURSUANT TO THE PLANS SUBMITTED.
HOIST TOWER, INSTALLATION AND OPERATION OF SINGLE RAXTAR RX3245 HOIST TOWER WITH 7,000 LBS. CAR CAPACITY, AS PER PLANS.