POST APPROVED OCCUPANCY CARD
FIRE ALARM: REPAIR EXISTING SYSTEM. AFFECTS: 0 DWELLING UNITS; 3 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 18TH FLOOR, 19TH FLOOR, PENTHOUSE.
CAB MODERNIZATION ON TWO(2) 4500LB CAPACITY, 17-FLOOR, PASSENGER ELEVATORS(#1 & #2); AND THREE(3) 3500LB CAPACITY, 53-FLOOR, PASSENGER ELEVATORS(#3-#5), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(100122137)
SCOPE: ROOF REPLACEMENT. AREA: 7600 SQ. FT. ROOF COVERING: OTHER. LOCATION: MAIN ROOF.. IL ROOFING CONTRACTOR LICENSE: 104000238.
MAINTAIN OR REPAIR ELECT ELEVA
WATER DAMAGE REPAIRS (SCOPE OF WORK MUST BE ON SITE) ON EG PASSENGER ELEVATOR; CAR 7, 5000LBS CAPACITY, 54 FLOORS, SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION (A/P #100122137).
No details available
REMOVAL OF 750LB CAPACITY, 55-FLOOR, BUILDING MAINTENANCE UNIT, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(100330791)
REMOVAL OF 750LB CAPACITY, 55-FLOOR, BUILDING MAINTENANCE UNIT, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(100330791)
REPLACE FEEDERS TO THE 3 EXISTING FIRE PUMP CONTROLLERS, 300 A, 200A, AND 100 AMPERE FEEDERS, RECONNECT THE EXISTING FEEDERS, GENERATOR, AND MOTOR LOADS, RECONNECT THE MONITORING WIRING.
DECOMMISSION BMU WINDOW WASHING UNIT, ROOF ANCHOR INSTALLATION PER STRUCTURAL ENGINEER'S DRAWINGS AND CALCULATIONS
SELF CERT 2019 CBRC: INTERIOR ALTERATIONS TO EXISTING CONDO UNIT 5101. WORK TO INCLUDE DEMO, NEW PARTITIONS, MECHANICAL, ELECTRICAL AND PLUMBING AS PER PLANS. R2 - RESIDENTIAL. 1A CONSTRUCTION
ERECT SIX (6) SCAFFOLDS 03/31/2023 TO 03/31/2024
ERECT 7 SCAFFOLDS 04/04/2022 TO 04/04/2023
100% CONCRETE COATING, 18,200 SQ FT BALCONY MEMBRANE OVERCOAT, 27,500 SQ FT CONCRETE ROUTE AND SEAL, 10,000 SQ FT WINDOW SEALANT REPLACEMENT, CONCRETE PATCHING 3650 SQ FT, BALCONY BASE PLATE REPLACEMENT- 400 EA, REMOVE AN REFASTEN METAL FINS - 200 EA, INSTALL ALUMINUM SLAB EDGE COVERS, 5,000 L FT REPLACE RAILING GASKETS. NO STRUCTURAL WORK.
INTERIOR LED RETROFIT
ERECT 1 SCAFFOLD 09/07/2021 TO 09/07/2022
INSTALL TWO 6" WATER COMPRESSION VALVES ON WATER SUPPLY AFTER METER.
No details available
PARKING GARAGE REPAIRS; TRAFFIC MEMBRANE INSTALL, 8000 SQ FT - CONCRETE REPAIRS; REPLACE CAST IRON PIPING AT FLRS 5, 6 & 7 AND REPLACE GARAGE DRAINS THROUGHOUT
ERECT ONE(1) SCAFFOLD FROM 08/03/2020 TO 08/03/2021.
INSTALLATION OF LOW VOLTAGE CCTV EQUIPMENT
REPLACE CAR TOP PARTS, CAR STATION PARTS, CAR DOOR & HOISTWAY PARTS, HOIST CABLES AND TRAVELING CABLES ON THREE(3) 53-FLOOR(38-STOP), 3500LB CAPACITY, 700FPM, PASSENGER ELEVATORS, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(100122137)WATER DAMAGE CARS #3,4,5
POST APPROVED OCCUPANCY CARD
OBSTRUCTIONS IN EXIT WAY
OWNER OR LICENSED CONTRACTOR
INSTALL
No details available
No details available
POST APPROVED OCCUPANCY CARD
REMOVE
OBSTRUCTIONS IN EXIT WAY
ARRANGE COMPLETED PERMIT INSP.
OBSTRUCTIONS IN EXIT WAY
PERMIT NOT POSTED AT SITE
REMOVE
ARRANGE COMPLETED PERMIT INSP.
PIPE OPENING W/NONCOMBUST MATL
POST OWNER/MANAGERS NAME/#
POST OWNER/MANAGERS NAME/#
CARB MONOX DETECT IN ASSEMBLY
MAINTAIN EXIT SIGN ILLUMINATED
INSTALL VENT/AS SHOWN ON PLANS
OPEN TYPE VIOLATION