POST APPROVED OCCUPANCY CARD
MAINTAIN EXIT SIGN ILLUMINATED
ARRANGE PREMISE INSPECTION
No details available
No details available
POST APPROVED OCCUPANCY CARD
OBSTRUCTIONS IN EXIT WAY
SOUTH ELEVATION: 6'-5" X 2'-3" LED ILLUMINATED CHANNEL LETTERS "DOLBY CINEMA" (INSTALLED ONTO THE EXISTING AMC SIGN)
No details available
FOR PERMIT B200022349: REPLACEMENT ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
ARRANGE PREMISE INSPECTION
REVISION TO PERMIT#101052155 CHANGE ELECTRICAL CONTRACTOR
SELF CERT 2019 CBC: INTERIOR DEMOLITION OF EXISTING 2ND FLOOR LUCKY STRIKE SPACE TO INCLUDE DEMOLITION OF EXISTING WALLS AND MILLWORK, NEW ELECTRICAL OUTLETS AND NEW PARTIAL HEIGHT PARTITION AS PER PLANS (OCCUPANCY A-3, TYPE IB CONSTRUCTION)
**FIRE ALARM PERMIT**FIRE ALARM SUBMITTAL. RENOVATIONS TO THE MECHANICAL PENTHOUSE LEVEL IN AN EXISTING HIGH-RISE BUILDING.
POST APPROVED OCCUPANCY CARD
REVISION TO PERMIT#101005281 CHANGE PLUMBING CONTRACTOR TO TRITON PLUMBING LLC
DDS: RENOVATION TO 20 OF 21 EXISTING THEATERS TO REPLACE EXISTING SEATS WITH LARGER RECLINERS. WORK TO INCLUDE REVISIONS TO STRUCTURAL PLATFORMS. OCCUPANCY TO BE REDUCED. NO CHANGES TO ROOM SIZE. OCCUPANCY A-1 THEATER; CONSTRUCTION TYPE IA. CONSULTANT REVIEWER: V3 COMPANIES OF IL
**FIRE ALARM** DISIGN, INSTALL AND TEST A NEW PRE-ACTION SYSTEM FOR TENANT BUILDOUT ON THE 2ND FLOOR OF AN EXISTING 58 STORY HIGH RISE PER CHICAGO BUIDING CODE CHAPTER 19. EXISTING FIRE ALARM SYSTEM TO REMAIN AND SHALL MONITOR THE NEW PRE-ACTION SYSTEM FOR ALARM AND TROUBLE. ELEVATOR RECALL IS NOT PART OF THIS SCOPE.
ARRANGE PREMISE INSPECTION
LOW-VOLTAGE
SELF CERT 2019 CBRC: INTERIOR ALTERATIONS TO EXISTING 2ND FLOOR SPACE TO INCLUDE REMOVAL OF NON LOAD BEARING WALLS, EQUIPMENT & CEILINGS, INSTALLATION OF NEW ROOMS AND MEP WORK AS PER PLANS (OCCUPANCY B & M, 1-A CONSTRUCTION)
**FIRE ALARM PERMIT**ALTERATIONS TO THE EXISTING TENANT ON FLOORS 1 & 2 IN AN EXISTING HIGH RISE BUILDING.
No details available
OBSTRUCTIONS IN EXIT WAY
POST APPROVED OCCUPANCY CARD
No details available
REPAIR ESCALATOR #2 DUE TO WATER DAMAGE( DOWN ESCALATOR) PER SCOPE OF WORK SUBMITTED.
**SELF-CERT PROJECT** BATHROOM ADDITION IN EXISTING GROUND FLOOR MERCANTILE SPACE AS PER PLANS
No details available
No details available
PERFORM REPAIRS ON TWO (2) 3500LB.CAP, 350 FPM, 6-STOPS, REPLACE HOIST ROPES ON ELEVATOR #P-3. REPLACE GOVERNOR #P-4. PURSUANT TO THE PLANS SUBMITTED. EV019311
No details available
POST APPROVED OCCUPANCY CARD
POST APPROVED OCCUPANCY CARD
ARRANGE COMPLETED PERMIT INSP.
OPEN TYPE VIOLATION
WALL & CEILING NO HOLES/CRACKS
POST APPROVED OCCUPANCY CARD
OBTAIN PERMIT BEFORE SIGN WORK
OBTAIN PERMIT BEFORE SIGN WORK
PRV PLUGGED/CAPPED
PRV PLUGGED/CAPPED
OBSTRUCTIONS IN EXIT WAY
REMOVE
PROVIDE
RECHARGE EXTINUISHERS