LINE VOLTAGE ELECTRICAL WORK. ADD 1 CIRCUITS TO EXISTING 60 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 3 . LIGHTING OUTLETS: 2. SPECIFIC LOCATION: BATHROOM.
REPAIR OR IN-KIND REPLACEMENT OF 0 PLUMBING FIXTURES AS DESCRIBED IN PERMIT APPLICATION. INCLUDES REPAIR OR REPLACMENT OF PLUMBING PIPING. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), FLOOR 39 UNIT 3901.
(SPR / 2019 CBRC) WATERPROOF BUILDING PERIMETER, EXTERIOR PLAZA RENOVATIONS TO INCLUDE, LANDSCAPING & MEP WORK AS PER PLANS. (TYPE IA CONSTRUCTION; OCCUPANCY CLASSIFICATION R2) **CERTIFIED PLANS CORRECTIONS: CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS **
SPR -2019 CBRC - SELECTIVE DEMOLITION TO AN EXISTING ROOFTOP AMENITY SPACE TO INCLUDE TENNIS COURT, PAVERS, SOIL, PLANTINGS, & WATERPROOFING MEMBRANE. INSTALL NEW WATERPROOF MEMBRANE AS PER PLANS. (TYPE IA CONSTRUCTION; OCCUPANCY CLASSIFICATION R2)
INTERIOR ELEC ALTERATIONS TO EXISTING CONDO DWELLING UNIT. WORK IN UNIT #3505, WORK PERFORMED FOR OWNER HISHAM YOUSIF.
INTERIOR ELEC ALTERATIONS TO EXISTING CONDO DWELLING UNIT. WORK IN UNIT #3809, WORK PERFORMED FOR OWNER JANICE HAY.
INTERIOR ELEC ALTERATIONS TO EXISTING CONDO DWELLING UNIT. WORK IN UNIT #2508, WORK PERFORMED FOR UNIT OWNER MICHAEL JAJI.
INTERIOR ELEC ALTERATIONS TO EXISTING CONDO DWELLING UNIT. WORK IN UNIT #2508, WORK PERFORMED FOR UNIT OWNER MICHAEL JAJI.
PULL EXISTING #14 WIRES TO LAUNDRY CLOSET OTLT, RUN NEW #12 WIRES FOR 20 AMP CIRCUITS. FURN/INST (2) 20 AMP SP BKRS + (2) 20 AMP OTLTS INSIDE LAUNDRY CLOSET AREA. REM/REPL (2) OTLTS IN KITCH COUNTER W (2) GFCI OTLTS. WORK IN UNIT# 1103, OWNER MICHAEL ZABRIN.
PULL EXISTING #14 WIRES TO LAUNDRY CLOSET OTLT, RUN NEW #12 WIRES FOR 20 AMP CIRCUITS. FURN/INST (2) 20 AMP SP BKRS + (2) 20 AMP OTLTS INSIDE LAUNDRY CLOSET AREA. REM/REPL (2) OTLTS IN KITCH COUNTER W (2) GFCI OTLTS. WORK IN UNIT# 1103, OWNER MICHAEL ZABRIN.
PARKSHORE MARKET LTD - 131-01395-04 - LOW VOLTAGE PERMIT FOR LOW VOLTAGE NON-REQUIRED FA/BA COMBO INSTALLATION
INTERIOR ELECTRICAL ALTERATIONS TO AN EXISTING CONDOMINIUM DWELLING UNIT. WORK IN UNIT# 2508, OWNER MICHAEL JAJI.
WORK IN UNIT 1008 ONLY: REPAIR/REPLACE DRYWALL,CHANGE VINYL FLOORING AND TILE,(ELECTRICAL HAS TO DONE ON LINE)PLUMBING(1)LAUNDRY TUB FAUCET,(1)KITCHEN SINK,INSTALL KITCHEN CABINETS.
No details available
INTERIOR ELECTRICAL ALTERATIONS TO AN EXISTING CONDOMINIUM DWELLING UNIT + FURNISH/INST. NEW CIRCUIT BREAKER PANEL. WORK IN UNIT# 2302, OWNER LEILA GREEN.
REPLACE RECEPTACLES LIGHTING
REPLACE COOLING TOWER AND TWO 500 TON CHILLERS. NEW COOLING TOWER ONE BAC MODEL PT2-1218A-3P1. NEW CHILLERS TWO YORK 500 TON, SELF CONTAINED, WATER COOLED, R134A, LOCATED ON THE ROOF.
REPLACE EXISTING LIGHT FIXTURES IN EXISTING LOCATION. ADD THREE OUTLETS IN NEW LOCATIONS. ADD OUTLET FOR THE FRIDGE IN NEW LOCATION.
UNIT 4701 ONLY - ALL NEW FIXTURES/FAUCETS INCL WATERLINE FOR DISHWASHER AND REFRIGERATOR, GARBAGE DISPOSAL, INSTALL IN SAME LOCATION AND CONNECTED TO EXISTING DRAINS/SUPPLIES; REPLACE CABINETS, COUNTERTOPS AND DRYWALL IN DINING/LIVING RM
KITCHEN / BATH REMODELING, NEW LIGHTS AND OUTLETS AND SWITCHES.ON EXISTING CIRCUITS
ERECT 1 SCAFFOLD 08.13.2021 - 08.13.2022
**FIRE ALARM PERMIT**FIRE ALARM PANEL REPLACEMENT TO A CITY APPROVED FIRE ALARM DETECTION AND VOICE COMMUNICATION SYSTEM
SEE INSPECTOR COMMENTS
SEE INSPECTOR COMMENTS
No details available
INSTALLATION OF A SEPARATE BOILER PLANT TO PROVIDE SPACE HEATING TO THE CONCOURSE LEVELS. DISCONNECTION FROM THE MAIN HEATING PLANT, ENERGY SAVINGS FROM THE REDUCED PUMP LOAD IN EXISTING 56 STORY MULTI-UNIT APARTMENT BUILDING.(CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS)
SECURITY SYSTEM WORK (CLUB ENTRANCE) (03-5262)
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA
MAINTAIN OR REPAIR HYDRO ELEVA