REPLACEMENT OF HOIST CABLES ON ONE(1) 3000LB CAPACITY, 21-FLOOR, 700FPM, PASSENGER ELEVATOR, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV004344)
No details available
WATER DAMAGE REPAIRS/REPLACEMENT ON ONE(1) 3000LB CAPACITY, 26-FLOOR, 600FPM, PASSENGER ELEVATOR(#18), PURSUANT TO THE SCOPE OF WORK ON LOCATION AT TIME OF INSPECTION. (EV004344)
WATER DAMAGE REPAIRS/REPLACEMENT ON ONE(1) 3000LB CAPACITY, 34-FLOOR, 600FPM, PASSENGER ELEVATOR(#20), PURSUANT TO THE SCOPE OF WORK ON LOCATION AT TIME OF INSPECTION.(EV004344)
WATER DAMAGE REPAIR/REPLACEMENT ON ONE(1) 3000LB CAPACITY, 16-FLOOR, 700FPM, PASSENGER ELEVATOR(#10), PURSUANT TO THE SCOPE OF WORK ON LOCATION AT TIME OF INSPECTION.(EV004344)
MAINTAIN OR REPAIR ELECT ELEVA
EMERGENCY PHONE UPGRADE ON FIVE(5) 3000LB CAPACITY, 14-FLOOR, 700FPM, PASSENGER ELEVATORS(#1-#5); AND FIVE(5) 3000LB CAPACITY, 29-FLOOR, 700FPM, PASSENGER ELEVATORS(#6-#10), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV004344)
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 0 . LIGHTING OUTLETS: 250. SPECIFIC LOCATION: SALON A MEETING ROOM.
EMERGENCY PHONE UPGRADE ON ELEVEN (11) ELEVATORS:3000LB.CAP, #11-#14, 21 FLR. #15 28FLRS. #17 26FLRS. #19 31FLRS. #20 34FLRS. #21 30FLRS. #22 30 FLRS. #23 4250LB.CAP.17FLRS. AND #26 5000LB.CAP, 8FLRS. GEARLESS TRACTION PASSENGER ELEVATORS. PURSUANT TO THE SCOPE OF WORK SUBMITTED. EV004344
TEMPORARY SCAFFOLDING: QTY: 5, MAX. LENGTH: 30 FT., MAX. HEIGHT: 300 FT. LOCATION: FACADE. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE THIS PERMIT IS NOT VALID WITHOUT CORRESPONDING CDOT PUBLIC WAY PERMIT.
SPR 2019 CBRC - STRUCTURAL PEER REVIEW REPORT. EXISTING 32 STORY HILTON HOTEL. REMOVE AND REPLACE EXISTING STEEL BEAMS AND STRUCTURAL SLAB IN A PORTION OF THE 3B BASEMENT LEVEL. REMOVE AND REINSTALL EXISTING STEEL GRATE; REPLACE ANGLE SUPPORTS. REMOVE AND RELOCATE EXISTING COMED SPLICE ROOM LOCATED ON THE 3B LEVEL SLAB BEING REPLACED. NEW LOCATION SHALL BE ON THE 4B LEVEL DIRECTLY BELOW EXISTING SPLICE ROOM. REMOVE AND REPLACE EXISTING MASONRY WALL SEPARATING THE BOILER ROOM FROM THE COMED SPLICE ROOM. REMOVE AND REINSTALL EXISTING REMOVABLE DOOR/FRAME/TRANSOM ASSEMBLY. PROVIDE ALL NEW COMED CABLES AND NEW CONDUIT PATH TO GET COMED CONDUITS TO EXISTING COMED NETWORK CENTER. ALL RELATED MEP/FP RELATED WORK, PER PLANS.
SPR 2019 CBRC - STRUCTURAL PEER REVIEW REPORT. EXISTING 32 STORY HILTON HOTEL. REMOVE AND REPLACE EXISTING STEEL BEAMS AND STRUCTURAL SLAB IN A PORTION OF THE 3B BASEMENT LEVEL. REMOVE AND REINSTALL EXISTING STEEL GRATE; REPLACE ANGLE SUPPORTS. REMOVE AND RELOCATE EXISTING COMED SPLICE ROOM LOCATED ON THE 3B LEVEL SLAB BEING REPLACED. NEW LOCATION SHALL BE ON THE 4B LEVEL DIRECTLY BELOW EXISTING SPLICE ROOM. REMOVE AND REPLACE EXISTING MASONRY WALL SEPARATING THE BOILER ROOM FROM THE COMED SPLIC
REPLACEMENT OF EXISTING REFRIGERATION RACK WITH A NEW ENVIRO-COOL 37.5 HP REFRIGERATION RACK, WATER COOLED, REMOTE, R448A, LOCATED IN THE UPDATED 2ND FLOOR RACK ROOM. ALL ASSOCIATED WORK INCLUDED. UPON COMPLETION OF WORK CONTACT CLEMENT GAVIN (REFRIGERATION BUREAU SUPERVISOR) FOR INSPECTION 312-743-7215.
REPLACEMENT OF EXISTING REFRIGERATION RACK WITH A NEW ENVIRO-COOL 37.5 HP REFRIGERATION RACK, WATER COOLED, REMOTE, R448A, LOCATED IN THE UPDATED 2ND FLOOR RACK ROOM. ALL ASSOCIATED WORK INCLUDED. UPON COMPLETION OF WORK CONTACT CLEMENT GAVIN (REFRIGERATION BUREAU SUPERVISOR) FOR INSPECTION 312-743-7215.
SELF-CERTIFICATION. INTERIOR RENOVATION OF AN EXISTING HOTEL POOL ROOM, INCLUDING REPLACEMENT OF THE FOLLOWING: POOL EQUIPMENT; FLOOR, WALL, AND CEILING FINISHES; LIGHT FIXTURES; POOL LINER; (2) HYDROTHERAPY SPAS; FLOOR DRAINS AND ASSOCIATED PIPING; AND ALTERATIONS TO EXISTING RESTROOMS TO CREATE AN ACCESSIBLE, ALL-GENDER, SINGLE USER RESTROOM. ALSO INCLUDED IS RELATED MODIFICATIONS TO MECHANICAL DUCTWORK, ELECTRICAL, PLUMBING, AND SPRINKLER LAYOUT AS PER PLANS.
SELF-CERTIFICATION. INTERIOR RENOVATION OF AN EXISTING HOTEL POOL ROOM, INCLUDING REPLACEMENT OF THE FOLLOWING: POOL EQUIPMENT; FLOOR, WALL, AND CEILING FINISHES; LIGHT FIXTURES; POOL LINER; (2) HYDROTHERAPY SPAS; FLOOR DRAINS AND ASSOCIATED PIPING; AND ALTERATIONS TO EXISTING RESTROOMS TO CREATE AN ACCESSIBLE, ALL-GENDER, SINGLE USER RESTROOM. ALSO INCLUDED IS RELATED MODIFICATIONS TO MECHANICAL DUCTWORK, ELECTRICAL, PLUMBING, AND SPRINKLER LAYOUT AS PER PLANS.
**FIRE ALARM PERMIT**THE MODIFICATION TO THE EXISTING APPROVED FIRE ALARM SYSTEM FOR A REMODELED AREA.
REPLACE TRAVELING CABLE ON ONE (1) 3000LB.CAP, 16-FLOOR, 700 FPM, GEARLESS TRACTION PASSENGER ELEVATOR #10. PURSUANT TO THE SCOPE OF WORK SUBMITTED. EV004344
HILTON - CANOPY - (S MICHIGAN AVE ELEVATION) - 3'-6" X 50'-0"W X 20'-0" DEPTH (5 SQFT OF SIGN ELEMENTS)
REPLACEMENT OF GOVERNOR CABLE ON ONE(1) 3000LB CAPACITY, 34-FLOOR, 600FPM, FREIGHT ELEVATOR(#20), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV004344)
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
NORTH & PARTIAL WEST ELEVATION, REBUILD LIMESTONE BALUSTRADES (55 EA), REBUILD WINDOW HEADS (577EA), REPLACE BRICK MASONRY, (1500EA), TUCKPOINT LIMESTONE/BRICK MASONRY (9000SQFT), REPLACE SEALANT (1400LF), LIMESTONE DUTCHMAN (500SQFT). ALL WORK SAME AS EXISTING.
INTERNAL
INTERNAL
OWNER OR LICENSED CONTRACTOR
HILTON - WALL SIGN - (E BALBO AVE ELEVATION) - 3'-6"H X 14'-2"W (50 SQFT)
HILTON - WALL SIGN - (E BALBO AVE ELEVATION - INSIDE PARKING GARAGE) - 3'-0"H X 12'-2"W (37 SQFT)
HILTON - CANOPY - (S MICHIGAN AVE ELEVATION / FACING NORTH) - 1'-2" X 4'-6"W (5 SQFT)
HILTON - CANOPY - (S MICHIGAN AVE ELEVATION / FACING SOUTH) - 1'-2" X 4'-6"W (5 SQFT)
No details available
ERECT FIVE (5) SCAFFOLDS DATES 04/14/2023 THROUGH 04/14/2024
REMOVE/REPLACE(APPROX 30,000SQ FT)OF EXISTING ROOF WITH LIKE KIND SYSTEM.
REPLACE HOIST ROPES ON ONE (1) 3000LB.CAP, 15-FLOORS, 700 FPM, GEARLESS TRACTION PASSENGER ELEVATOR #3. PURSUANT TO THE SCOPE OF WORK SUBMITTED. EV004344
**FIRE ALARM PERMIT**THE MODIFICATION TO THE EXISTING APPROVED FIRE ALARM SYSTEM FOR A REMODELED AREA.
SELF CERT 2019 CBRC: NO STRUCTURAL MODIFICATIONS TO EXISTING CANOPY STRUCTURE. REFURBISH EXISTING CANOPY LOCATED AT MAIN ENTRANCE. SELECTIVE DEMOLITION OF EXISTING CANVAS CEILING, DOWN LIGHTS, INFRARED HEAT AND METAL FASCIA. REMOVE, REFURBISH AND RE-INSTALL CANOPY CHANDELIERS. INSTALL NEW EXTERIOR SOFFIT BOARD AND CEILING. INSTALL NEW ORNAMENTAL METAL FASCIA. INSTALL NEW LED RECESSED DOWN LIGHTS. INSTALL OF NEW INFRARED HEATERS. TEMPORARY REMOVE AND RE-INSTALL CAB LIGHT, SPEAKERS AND SECURITY CA
REPLACE ONE EXISTING CHILLER WITH ONE YORK 900 TON CHILLER, SELF CONTAINED, WATER COOLED, R134A, LOCATED IN THE BASEMENT MECHANICAL ROOM. CONTACT BUD GAVIN (REFRIGERATION BUREAU SUPERVISOR) FOR INSPECTION UPON THE COMPLETION OF WORK, 312-743-7215.
SEALANT REPAIR, FACADE CLEANING, REPAIR 226 LINTELS ALL TWO AND A HALF FEET LONG
ERECT TWO (2) SCAFFOLDS DATES 09/23/2022 THROUGH 09/23/2023
REPLACE HOIST ROPES ON PASSENGER ELEVATOR #14, 3000LBS CAPACITY, 25 FLOORS, SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION (EV004344).
MAINTAIN OR REPAIR ELECT ELEVA
COMPLETE ROOF REPLACEMENT.
HOIST CABLE REPLACEMENT ON ONE(1) 3000LB CAPACITY, 21-FLOOR, 700FPM, PASSENGER ELEVATOR(#12), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV004344)