LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL DATA/VIDEO. SPECIFIC LOCATION: UNIT 4.
SEFT-CERT 2019 CBRC: ALTERATIONS TO AN EXISTING BUILDING ON GROUND FLOOR OF AN EXISTING COMMERCIAL SPACE APPROXIMATELY 885 SF.FT. THE SCOPE OF WORK SHALL CONSIST OF BUT IS NOT LIMITED TO THE FOLLOWING: SELECTIVE DEMOLITION AND CONSTRUCTION OF SUSPENDED CEILINGS, NON-STRUCTURAL PARTITIONS, LIGHTING, FINISHES, FURNITURE/CASEWORK, ASSOCIATED MECHANICAL/PLUMBING, ELECTRICAL/TELECOMMUNICATIONS SYSTEMS-FIRE ALARM AND SPRINKLER TO BE UNDER SEPARATE PERMIT : CURRENT OCCUPANCY GROUP M, TYPE 1A CONSTRUCTI
SPR 2019 CBRC: INTERIOR ALTERATIONS TO THE HIGH SCHOOL LOCATED ON FLOOR 7 OF AN EXISTING 16 FLOOR BUILDING. ADDING TWO INTERIOR PARTITIONS TO DIVIDE EXISTING CLASSROOMS AND ADDING A NEW DOOR. NEW/RELOCATED ELECTRICAL OUTLETS, SWITCHES, AND DOOR SIDELIGHT. (OCCUPANCY GROUP E-1, TYPE IA CONSTRUCTION)
REPLACEMENT OF HOIST CABLES ON ONE(1) 3500LB CAPACITY, 12-FLOOR, 500FPM, PASSENGER ELEVATOR(#2), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV006517)
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: BUSINESS. START DATE: 11/7/2024. END DATE: 11/7/2025. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: BUSINESS. START DATE: 10/7/2024. END DATE: 11/6/2024. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.
MONTHLY MAINTENANCE PERMIT
MONTHLY MAINTENANCE PERMIT
MONTHLY MAINTENANCE PERMIT
MONTHLY MAINTENANCE PERMIT
MONTHLY MAINTENANCE PERMIT
MONTHLY MAINTENANCE PERMIT
INSTALLATION OF NEW THREE-PAN SINK IN CAFETERIA/MULTIPURPOSE ROOM WITHIN MUCHIN COLLEGE PREP SCHOOL. SINK TO BE TIED INTO EXISTING PLUMBING. NO EXTERIOR WORK LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), 7TH FLOOR, ROOM UO5
MONTHLY MAINTENANCE PERMIT
MONTHLY MAINTENANCE PERMIT
MONTHLY MAINTENANCE PERMIT
MONTHLY MAINTENANCE PERMIT
MONTHLY MAINTENANCE PERMIT
MONTHLY MAINTENANCE PERMIT
BURLINGTON COAT FACTORY - 130-53202-09 - LOW VOLTAGE PERMIT FOR LOW VOLTAGE BURGLAR ALARM INSTALLATION
REPLACEMENT OF TWO GLASS DOORS AND SIDELITES AT 7TH FLR PER ARCHITECT'S DRAWING. NO EXTERIOR WORK.
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
SELF-CERT 2019 CBRC: INTERIOR ALTERATION TO AN EXISTING EDUCATIONAL SPACE IN HIGH RISE TOWER. REMOVAL OF RATED DOOR AND GLASS STOREFRONT ON 7TH FLOOR SPACE. NO STRUCTURAL WORK; NO CHANGES TO EXISTING LIFE SAFETY FIRE PREVENTION OR EGRESS. (OCCUPANCY GROUP E-1; TYPE IA CONSTRUCTION)
MAINTAIN OR REPAIR ESCALATOR
**FIRE ALARM PERMIT** ** FIRE ALARM PERMIT ** INSTALLATION OF ELECTROMAGNETIC LOCKING DEVICES PER CBC SECTIONS 10(13-160-269) AND 10(13-160-260) ON FLOOR 13.
**FIRE ALARM PERMIT**ADDING NEW FIRE ALARM RELAY ON THE 13TH FLOOR FOR TENANT DOOR RELEASE
LOW VOLTAGE A/V INSTALLATION ON 7TH FLOOR FOR CHICAGO COMMUNITY TRUST.
MAINTAIN OR REPAIR ESCALATOR
MODERNIZATION OF TWO(2) 4451LB CAPACITY, 100FPM, ECO3000 ESCALATORS, PURSUANT TO THE SCOPE OF WORK PLANS SUBMITTED.(EV006517) 2-3 UP, 3-2 DOWN
SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS TO AN EXISTING HIGH SCHOOL. CONVERSION OF OPEN OFFICE ADMINISTRATIVE SPACE TO THREE ADDITIONAL CLASSROOMS; NON-STRUCTURAL DEMOLITION TO COMBINE TWO EXISTING CONFERENCE ROOMS TO ONE ADDITIONAL CLASSROOM. EXISTING OCCUPANCY EDUCATIONAL GROUP E-1 DOES NOT CHANGE. (OCCUPANCY E-1, CONSTRUCTION TYPE 1A)
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MODERNIZATION OF TWO (2) ESCALATORS, #1 1-2 UP/SL#: 350475674; NETWORK 7180173, #2 2-1 DN/SL#:350475675; NETWORK: 7180174. PURSUANT TO THE PLANS SUBMITTED. EV006517
INSTALLATION OF ONE (1) 2500LB.CAP, 150 FPM, 6-8MM CABLES, 2:1 ROPING, NOT ADA COMPLIANT KONE MONO SPACE 500 FBR ELEVATOR #1/NETWORK 71874284, STAATE STREET ELEVATOR. PURSUANT TO THE PLANS SUBMITTED TO REPLACE ELEVATOR REMOVED UNDER PERMIT # 100919423. EV006517
DECOMMISSION/EXISTING ELEVATOR REMOVAL-ELEVATOR A (STATE STREET HYDRO ELEVATOR) SERVES 4 -FLOORS, 100 FPM, BEING REPLACED WITH KONE MONO SPACE 500 FPM ELEVATOR ON A NEW PERMIT. PURSUANT TO THE SCOPE OF WORK SUBMITTED. EV006517
REPLACEMENT OF HOIST CABLES ON ONE(1) 6000LB CAPACITY, 21-FLOOR, 350FPM ELEVATOR, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV006517) CAR#31
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
SELF-CERT 2019: CBRC INTERIOR RENOVATION TO EXISTING RESTROOMS ON THE 12TH FLOOR OF 16 FLOOR OFFICE BUILDING AT 1 N STATE. (OCCUPANCY GROUP B; TYPE 1A CONSTRUCTION).
SELF-CERT 2019: CBRC INTERIOR RENOVATION TO EXISTING RESTROOMS ON THE 8TH FLOOR OF 16 FLOOR OFFICE BUILDING AT 1 N STATE. (OCCUPANCY GROUP B; TYPE 1A CONSTRUCTION).
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
**FIRE ALARM PERMIT**** FIRE ALARM PERMIT** INSTALLATION OF ELECTROMAGNETIC LOCKING DEVICES PER CBC SECTIONS 10(13-160-269) & 10(13-160-260) ON FLOOR 10.
REVISION TO PERMIT # 100844930 TO CHANGE GC TO BEAR CONSTRUCTION COMPANY