No details available
No details available
No details available
DDS 2019 CBRC: REVISION TO DDS PERMIT 100987508. THIS REVISION SCOPE OF WORK INCLUDES CHANGES TO THE HVAC SYSTEM, STRUCTURAL WORK FOR THE ROOFTOP EQUIPMENT, AND THE ADDED RADON SYSTEM. CHANGES TO THE LAYOUT OF THE FIRST FLOOR COMMON-AREA TOILET ROOMS. 1A CONSTRUCTION. R-2 RESIDENTIAL. CONSULTANT REVIEWER: GLOBETROTTERS ENGINEERING
DDS 2019 CBRC: REVISION TO DDS PERMIT 100987508. THIS REVISION SCOPE OF WORK INCLUDES CHANGES TO THE HVAC SYSTEM, STRUCTURAL WORK FOR THE ROOFTOP EQUIPMENT, AND THE ADDED RADON SYSTEM. CHANGES TO THE LAYOUT OF THE FIRST FLOOR COMMON-AREA TOILET ROOMS. 1A CONSTRUCTION. R-2 RESIDENTIAL. CONSULTANT REVIEWER: GLOBETROTTERS ENGINEERING
DDS 2019 CBRC: INTERIOR ALTERATIONS TO EXISTING 145 APARTMENT 12 STORY BUILDING TO INCLUDE SELECTIVE DEMO, MEP INFRASTRUCTURE UPGRADES, ROOF REPLACEMENT, LIMITED WINDOW REPLACEMENT, CHILLER AND BOILER REPLACEMENT IN BASEMENT, 1ST FLOOR LOBBY ALTERATIONS TO OFFICE AND FITNESS CENTER, TYPICAL WORK ON FLOORS 2-12 AS PER PLANS. 1A CONSTRUCTION. R-2 RESIDENTIAL, CONSULTANT REVIEWER: GLOBETROTTERS ENGINEERING
REPLACE MACHINE ON NORTH PASSENGER ELEVATOR, 2000LBS CAPACITY, 12 STOPS, SUBJECT TO CITY OF CHICAGO DEPT. OF BULDINGS ELEVATOR BUREAU INSPECTION (EV005312).
TUCKPOINTING(1000 FT) AND LINTEL REPLACEMENT(ALL UNDER 6FT)CAULKING - NO STRUCTURAL WORK - 1 SQFT
REMOVE EXISTING COFFEE EQUIPMENT AND REPLACE WITH NEW EQUIPMENT AND RELOCATE TWO 30 AMP RECEPTACLES AND THREE 20 AMP RECEPTACLES
TUCKPOINTING, LINTEL REPLACEMENT NOT TO BE GREATER THAN 6' IN LENGTH (NORTH ELEVATION)
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
ARRANGE PREMISE INSPECTION
MODERNIZATION OF ONE (1) 2000LB.CAP, 12-FLOOR, GEARED TRACTION PASSENGER ELEVATOR #1S. PURSUANT TO THE SCOPE OF WORK SUBMITTED. EV005312
"ALL ELEVATIONS, CONDUCT EXTERIOR WALL CRITICAL EXAM HANDS ON INSPECTION WITH TWO MASONRY OPENINGS, REPAIR/REPLACE LINTEL, REPAIR/REPLACE 40X40 PANEL, REPAIR/REPLACE 2 PCS FINALS, ONLY" SUBJECT TO FIELD INSPECTIONS
REPLACEMENT OF WIC & RIC LIKE FOR LIKE SYSTEMS WITH HEATCRAFT CONDENSING UNITS, ONE 4HP, ONE 3/4 HP, REMOTE, AIR COOLED, R404A, LOCATED ABOVE THE COOLER.ALL DEVICES AND COMPONENTS INCLUDED.
No details available
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
ARRANGE PREMISE INSPECTION
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
MAINTAIN OR REPAIR ELECT ELEVA
SEND EX. METAL LETTER