1110 N Lake Shore Dr, Chicago, IL, 60611 · Chicago · 39 total events
LINE VOLTAGE ELECTRICAL WORK. NEW TEMPORARY 800 AMP SERVICE DISCONNECTING MEANS WITH 15 CIRCUITS. RECEPTACLE OUTLETS: 10 . LIGHTING OUTLETS: 6. SPECIFIC LOCATION: 39/40TH FLOORS BLD COMMON AREAS.
SCOPE: NONSTRUCTURAL INTERIOR ALTERATION, RECONFIGURE CLOSETS AND DOORS, NEW MILLWORK, REPLACE PLUMBING AND ELECTRICAL FIXTURES WITH ASSOCIATED PIPING. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), UNIT 19N.
CONCRETE MASONRY REPAIR / REPLACEMNT: 525SQ. FT., EXCAVATION = NO. LOCATION: EXTERIOR BUILDING.
TEMPORARY SCAFFOLDING: QTY: 2, MAX. LENGTH: 24 FT., MAX. HEIGHT: 480 FT. LOCATION: EXTERIOR BUILDING. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE
FOR PERMIT 101051708: REPLACEMENT ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: APARTMENT 14N.
LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL OTHER. SPECIFIC LOCATION: GARAGE DRIVEWAY, BOILER ROOM.
REMV OLD DISCONNECT/TRANSFORMER/PUSH-TO-START DISCONNECT, FURN/INST ALL-IN-ONE MTR STRTR DISCONNECT W SELECTOR SW. FURN/INST A LOW VOLTAGE CAB LT ABOVE FRNT ENT CANOPY + RUN NEW CONDUIT CLOSER TO THE CORNER ON SIDE OF BLDG + CONTINUE RUN TO DEISRED LOC FOR NEW CAB LT. WORK PERFD FOR 1110 LAKE SHORE DR CA.
SELF CERT 2019 CBRC. INTERIOR REMODELING OF EXISTING UNIT 27N IN HIGH RISE CONDO BUILDING AS PER PLANS. NO HVAC WORK.
NONSTRUCTURAL INTERIOR KITCHEN AND BATHROOM ALTERATION OF EXISTING CONDOMINIUM UNIT 32S. REPLACEMENT OF ELECTRICAL FIXTURES, PLUMBING FIXTURES, AND MATERIAL FINISHES PER PLANS.
FURNISH/INSTALL A 20 AMP DECORA OUTLET NEXT TO INTERNET MODEM ON WALL SHELF W RACEWAY RAN BEHIND THE DRYWALL FROM NEW OUTLET. WORK PERFORMED FOR 1110 LAKE SHORE DR CA.
SCOPE: NONSTRUCTURAL INTERIOR ALTERATION.LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), APARTMENT 22S. THE SCOPE OF RENOVATION WORK INCLUDES NEW PAINT, RUNNING TRIM, NEW WOOD FLOORING THROUGHOUT; A NEW KITCHEN WITH ISLAND OPENED TO THE MAIN LIVING SPACE; A NEW PRIMARY BATHROOM AND PRIMARY CLOSET; NEW POWDER ROOM VANITY, TOILET; RELOCATION OF A WASHER AND DRYER REPLACE IN PLACE LIGHTING FIXTURES.
**FIRE ALARM PERMIT**ADDITION TO CITY OF CHICAGO EXISTING FIRE ALARM SYSTEM PER 14B-9-907.2 CHICAGO BUILDING CODE.
KITCHEN AND BATHROOMS ELECTRICAL REMODELING
REPAIR OR IN-KIND REPLACEMENT OF 12 PLUMBING FIXTURES AS DESCRIBED IN PERMIT APPLICATION. INCLUDES REPAIR OR REPLACMENT OF PLUMBING PIPING. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 3 INTERIOR COMMON AREAS, KITCHEN AND 2 BATHROOMS.
CLOSET: REMV OLD STAB LOCK PNL FROM CLOSET, FURN/INST (1) NEW 200 AMP MAIN LUG ELEC PNL W/40 CIRCUITS + INT ELEC ALTS TO EXISTING CONDO DWELLING UNIT. WORK IN UNIT #14S, UNIT OWNER TODD BLOCKINGER.
SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS TO AN EXISTING 39TH FLOOR AMENITY SPACE IN AN EXISTING RESIDENTIAL HIGH-RISE CONDO BUILDING AS PER PLANS. WORK TO INCLUDE SELECTIVE DEMOLITION, NEW PARTITIONS, LIGHTING,FINISHES, MECHANICAL, PLUMBING AND ELECTRICAL. NO STRUCTURAL WORK. (CONSTRUCTION TYPE: II-A; OCCUPANCY: R-2RESIDENTIAL)
INSTALLATION OF NEW GLIDE P DOOR OPERATORS ON TWO(2) 2000LB CAPACITY, 500FPM, 41-FLOOR, PASSENGER ELEVATORS, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV003394)
SELF-CERT 2019 CBRC:REMODELING OF 2 CONDO UNITS IN MULTIFAMILY CONDO BUILDING (OCCUPANCY GROUP R-2; TYPE IA CONSTRUCTION)
INTERIOR ELEC ALTERATIONS TO EXISTING CONDO DWELLING UNIT. FOR WORK IN UNIT 16N, OWNER MIKE NOWAK.
REMOVE OLD 200 AMP PANEL AND REPL W NEW 200 AMP 40 CIRC ELEC PANEL. FOR WORK IN UNIT 16N, OWNER MIKE NOWAK.
INSTALL HEATED PANELS IN LIVING ROOM CEILING. FOR WORK IN UNIT 6S, OWNER JENNIFER MARTINEZ.
REPAIR AND REPLACE ROUGHLY 3 FEET OF PIPE ON A 6 INCH VENT STACK. WORK AND REPAIR WILL BE DONE ON 5TH FLOOR ONLY.
SELF-CERT: INTERIOR ALTERATIONS OF EXISTING 1,564 SQ. FT. R-2 SPACE. PROVIDE NEW WALLS AND DOORS. PROVIDE NEW INTERIOR FINISHES. PROVIDE NEW PLUMBING WORK. PROVIDE NEW MECHANICAL WORK. PROVIDE NEW ELECTRICAL AND LIGHTING WORK. MECHANICAL WORK (EXISTING TO REMAIN) - NO WORK, AS PER PLANS.
**FIRE ALARM PERMIT****FIRE ALARM PERMIT** REPLACE EXISTING PNEUMATIC RELEASE OF SMOKE STAIRWELL SMOKE DAMPER BY ADDING SMOKE DETECTION FOR RELEASE ON AN CHICAGO APPROVED HI RISE FIRE ALARM SYSTEM.
REPLACE ELECTRICAL PANEL AND ADD KITCHEN CIRCUITS FOR UNIT 8S
ADD NEW CIRCUITS AND REPLACE ELECTRICAL PANEL FOR UNIT 8S
REPLACE ELECTRICAL PANEL, NEW ELECTRICAL IN KITCHEN AND BATHROOM, REPLACE ALL SWITCHES AND RECEPTACLES.
REPAIR AND REPLACE PLUMBING FIXTURES AND ALL D,W,V AND WATER PIPING FOR [3] FULL BATHROOMS AND KITCHEN/ LAUNDRY.FOR UNIT 8S ONLY.NO WATER HEATER INSTALLATION ON THIS PERMIT.
ADD OUTLETS ON EXISTING CIRCUITS FOR KITCHEN AND BATH REMODEL. UNIT NUMBER 8S
NEW OUTLETS AND LIGHTS IN THE ENGINEERS UNIT
ERECT THREE(3)SCAFFOLDS FROM 05/18/2021 TO 05/18/2022.
INTERIOR ALTERATIONS TO EXISTING CONDO UNIT #28N. NO STRUCTURAL WORK TO BE DONE. NO CHANNELING OF EXISTING FIRE RATED ASSEMBLIES IS PERMITTED. NO WORK AND REMOVALS TO CHASE AND COLUMN ENCLOSURES. ALL WORK AS PER PLANS.
UNIT#28N - REPLACE KITCHEN CABINETS, CERAMIC TILES, HARDWOOD FLOORING, DOORS, REPAIR & REPLACE DRYWALL AS NEEDED, AND PAINTING. ALL WORK SAME AS EXISTING.
INTERIOR BUILDOUT OF RESIDENTIAL CONDOMINIUM UNIT. EXISTING A-2 RESIDENTIAL CONDOMINIUM UNIT.
"ALL ELEVATIONS, REPAIR CMU SEAL CRACKS 9000 L FT., REPAIR CONCRETE CRACKS 1500 SQ. FT., REPAIR CONCRETE SPALLS 300 SQ. FT., REPLACE HOPPER WINDOWS PANELS FASTENERS 100 ANCHORS, REPAIR METAL COPING, REPLACE WINDOW PERIMETER SEALANT 100% AROUND ALL WINDOWS & GLAZING AND HOPPER WINDOWS & CMU WALL & AT A/C UNITS, REPAIR/REPLACE WEEP SYSTEM AT HOPPER WINDOW, ONLY"
ERECT THREE SCAFFOLDS FROM 03/26/2019 TO 03/26/2020.
REMODEL KITCHEN, BATHROOMS, CLOSETS AND RELOCATE WASHER AND DRYER IN UNIT #17S AS PER PLANS.
REPLACING RECEPTACLES, SWITCHES AND LIGHT FIXTURES.